Difficulty

Moderate

Steps

8

Time Required

                          10 - 30 minutes            

Sections

1

  • Reverse Switch
  • 8 steps

Flags

0

  • BackGeneral Pipe Cleaners “The Metro” Drain Cleaner, model PMEBO (2016)

  • Full Screen

  • Options

  • History

  • Save to Favorites

  • Download PDF

  • Edit

  • Translate

  • Get Shareable Link

  • Embed This Guide

  • Notify Me of Changes

  • Stop Notifications

Introduction

What you need

Step 1

              Reverse Switch               
  • Before you begin, make sure the drain cleaner is disconnected from power.
  • Use a Phillips #2 driver to remove the two screws securing the control box cover.

Before you begin, make sure the drain cleaner is disconnected from power.

Use a Phillips #2 driver to remove the two screws securing the control box cover.

1024

Step 2

  • Remove the control box cover.

Remove the control box cover.

Step 3

  • Use a 9/16 inch deep socket and ratchet to remove the nut securing the reverse switch.

Use a 9/16 inch deep socket and ratchet to remove the nut securing the reverse switch.

Step 4

  • Remove the reverse switch guard.

Remove the reverse switch guard.

Step 5

  • Squeeze the tabs on either side of the reverse switch connector.
  • Pull the two halves of the connector apart to disconnect it.
  • Take note of where everything is connected in the control box before disconnecting anything else.

Squeeze the tabs on either side of the reverse switch connector.

Pull the two halves of the connector apart to disconnect it.

Take note of where everything is connected in the control box before disconnecting anything else.

Step 6

  • Pull the white cable straight off of its spade connector on the power switch diaphragm.

Pull the white cable straight off of its spade connector on the power switch diaphragm.

Step 7

  • Pull the black cable straight off of its spade connector on the power switch diaphragm.

Pull the black cable straight off of its spade connector on the power switch diaphragm.

Step 8

  • Slide the switch assembly down out of its hole in the control box and pull it out of the control box.
  • Be careful not to snag the switch on any cables during removal.

Slide the switch assembly down out of its hole in the control box and pull it out of the control box.

Be careful not to snag the switch on any cables during removal.

To reassemble your device, follow these instructions in reverse order.

Cancel: I did not complete this guide.

Author

                    Adam O'Camb                     

Member since: 04/11/2015

173,479 Reputation

                                      418 Guides authored                  



                       Badges:
                       39







                                                        +36 more badges