2
- Top Cover
- 5 steps
- How to Adjust Black and Decker TR1278B Browning Dial
- 4 steps
Flags
0
BackBlack and Decker TR1278B
Full Screen
Options
History
Save to Favorites
Download PDF
Edit
Translate
Get Shareable Link
Embed This Guide
Notify Me of Changes
Stop Notifications
Introduction
What you need
Step 1
Top Cover
- Unplug the toaster before disassembly.
- Remove the carriage lever by pulling it away from the toaster.
Unplug the toaster before disassembly.
Remove the carriage lever by pulling it away from the toaster.
1024
Step 2
- Toaster will be turned upside down. Clear crumb tray or work over a paper towel.
- Turn the toaster upside down.
- Unscrew all four 4mm screws on the bottom using a Phillip’s head #2 (PH2) screwdriver.
Toaster will be turned upside down. Clear crumb tray or work over a paper towel.
Turn the toaster upside down.
Unscrew all four 4mm screws on the bottom using a Phillip’s head #2 (PH2) screwdriver.
Step 3
- Detach the bottom from the front cover using the plastic opening tool.
Detach the bottom from the front cover using the plastic opening tool.
Step 4
- Turn the toaster right side up.
- Support the bottom. The ribbon cable that connects the toaster to the front cover can be damaged.
- Lift the front cover.
- Lift carefully. Again the ribbon cable can be damaged.
Turn the toaster right side up.
Support the bottom. The ribbon cable that connects the toaster to the front cover can be damaged.
Lift the front cover.
Lift carefully. Again the ribbon cable can be damaged.
Step 5
- Detach the bundled cable connector from the toaster by carefully pulling it away from the circuit board.
Detach the bundled cable connector from the toaster by carefully pulling it away from the circuit board.
Step 6
How to Adjust Black and Decker TR1278B Browning Dial
- Remove the front cover.
Remove the front cover.
Step 7
- Unscrew the circuit behind the browning dial on the front cover.
- Do not lose the washers on the screws.
Unscrew the circuit behind the browning dial on the front cover.
Do not lose the washers on the screws.
Step 8
- Remove the circuit.
- The dial and buttons on the front cover will be loose.
Remove the circuit.
The dial and buttons on the front cover will be loose.
Step 9
- Turn the knob on the circuit board left or right to adjust the browning dial.
Turn the knob on the circuit board left or right to adjust the browning dial.
To reassemble your device, follow these instructions in reverse order.
Cancel: I did not complete this guide.
Author
with 3 other contributors
Dominic Gamonez
Member since: 02/15/2017
224 Reputation
2 Guides authored
Badges:
5
+2 more badges
Team
USF Tampa, Team 8-1, Eyestone Spring 2017
Member of USF Tampa, Team 8-1, Eyestone Spring 2017
USFT-EYESTONE-S17S8G1
3 Members
5 Guides authored